Duckbill valve classification: socket-style duckbill valve, mosaic duckbill valve, duckbill valve flange, install the plate duckbill valve, duckbill valve, built-duckbill valve. 
Duckbill valve installation: Flange duckbill valve installed in the drain outlet end with a flange. Duckbill valve installed in the socket-type drain export, mosaic duckbill valve installed in the middle of the city sewer pipes. Installation plate Duckbill valve installed in the outlet end of the buildings. Built-duckbill valve installed in the city sewer and water system ends. Mortar or cement pipeline duckbill valve installed in the mortar or cement pipe end.  
Duckbill valve installation method and size: the rubber flange, made of one body and beak, and the metal flange with a gasket, you can connect with the natural metal flange, directly installed in the tank, pipes and cofferdam on. Installation connection, flange and flange dimensions correspond to the flange with the flange, as the case should be added between the waterproof glue, sealed to ensure absolute connection after fastening, but also be careful not to break something duckbill valve flange lips. Duckbill valve Material: Neoprene, Haipu Long, nitrile rubber and ethylene-propylene rubber.     Flexible rubber duckbill valves, also known as check valves, slow closing check valve rubber, rubber sewage check valve. XH81, XH81A, XH41, XH41A duckbill-type valve (Spain called "flexible duckbill check valve"; the United States known as the "duckbill valve rubber flat mouth") is a valve company in Spain ROSS, American Red Valve Company production based on the summary, exemplary, revolutionary re-design. We are committed to continuous improvement (duckbill check valve flexible) rubber discharge check valve function, improve performance, so that the valve of the strength, toughness, sealing greatly improved, the valve does not have any active components, the avoidance of maintenance. The valve can give straight pipe, flange pipe, concrete pipe, glass pipe support, the valve is widely used in coastal, beach, docks, reservoirs, municipal drainage, sewage, can be described as environmentally friendly green valve, the valve replacement door check valves, door easily solve the sediment, silt, rocks, vegetation, marine life blocking problems. 
    
        
             
        

             
        XH81 type - DN20-2000mm 
            XH41 type - DN100-2000mm 
        
             
        

             
        XH81A type - DN200-1200mm 
            XH41A type - DN200-600mm 
        
             
    
             
        
                
                    
            
                         
                    
                         
                    
                            
                                
                        
                                     
                                DN 
                                    With the pipe diameter 
                                    Valve port level (A) 
                                    Pipeline access (B>) 
                                
                                     
                                50 
                                    2 " 
                                    20 
                                    20 
                                
                                     
                                65 
                                    2 "-1 / 2" 
                                    25 
                                    25 
                                
                                     
                                80 
                                    3 " 
                                    40 
                                    40 
                                
                                     
                                100 
                                    4 " 
                                    50 
                                    50 
                                
                                     
                                150 
                                    6 " 
                                    50 
                                    50 
                                
                                     
                                200 
                                    8 " 
                                    50 
                                    50 
                                
                                     
                                250 
                                    10 " 
                                    50 
                                    50 
                                
                                     
                                300,350 
                                    12 "~ 14" 
                                    100 
                                    100 
                                
                                     
                                400,450,500 
                                    16 "~ 20" 
                                    150 
                                    150 
                                
                                     
                                600,700,800,900 
                                    24 "~ 36" 
                                    200 
                                    200 
                                
                                     
                                1000 
                                    40 " 
                                    250 
                                    250 
                                
                                     
                                1200,1400,1600 
                                    64 " 
                                    300 
                                    300 
                                
                                     
                                1800 
                                    72 " 
                                    400 
                                    400 
                                
                                     
                            
                        Description: DN800 ~ 1800 (32 "~ 72") for the double-clad hoop 
                                
                         
                    Schematic diagram 
                    
                         
                      
                    
                         
                    Use on-site 
                        Installation structure 
                    
                         
                    
                         
                    
                            
                                
                        
                                     
                                Installation 
                                    Installation location 
                                    Installation Schematic 
                                
                                     
                                Socket type 
                                    Installed in the discharge  
                                    
                                    pipe of the 
                                    mouth
                                     
                                Flange 
                                    Installed in the discharge  
                                    
                                    pipe with a method 
                                    of export blue 
                                    end
                                     
                                Mosaic 
                                    Installed in the City  
                                    
                                    Municipal water pollution 
                                    in the water pipes 
                                    between the
                                     
                                Installation Plate 
                                    Installed at the  
                                    
                                    water end of the construction of 
                                    buildings on
                                     
                                Built-in 
                                    Installed in the City  
                                    
                                    Urban rainwater sewage 
                                    system, water and 
                                    effluent ends
                                     
                            
                        Mortar or water  
                                    
                                    mud pipelineInstalled on the gray  
                                    
                                    cement slurry or 
                                    the end of the pipe 
                                    end
                         
                      
                    
                         
                    
                         
                      
                    
                         
                    
                         
                      
                    
                         
                    
                         
                      
                    
                         
                    
                         
                    Storage and transport precautions: 
                    
                        A, XH81, XH41 type of duckbill valves, should be kept in a cool, dry place, and to ensure that state transportation vertical placement; 
                        B, set above the ground level floor or stand up; 
                        C, the valve doors away from heat, ozone, oil, acid, alkali region;
                         
                
            D, non-light radiation exposure and strong load-bearing; E, non-sharp instruments cut through the surface; F, the box marked "↑", does not allow upside down or flat. 
                    
 